Chemical Library and Synthesis Scale-Up Service
Facility description
The Institute of Chemical Research (IIQ) is one of the three nodes of the CSIC Chemical Library, with the Chemical Library and Synthesis Scale-Up Service being responsible for managing the collection of compounds deposited at this center.
The Service is equipped with a range of instruments that, in addition to their routine use within the Compound Library, can also be employed for research activities.
Equipment
The Chemical Library and Synthesis Scale-Up Service is equipped with the following scientific instrumentation:
Self-service equipment available through time reservation:
- H-Cube Mini Plus (ThalesNano): Hydrogenation of compounds in continuous flow with in situ H₂ generation.
- Biotage Initiator+: Microwave synthesis reactor.
- Biotage Selekt: Low- and medium-pressure chromatography for the purification of organic molecules.
- Chemglass jacketed reactor system with capacities ranging from 100 mL to 5 L.
Equipment operated by the Service’s technical staff:
- Opentrons OT-2: Robotic pipetting platform for automated preparation of sampling plates, sample dilution, etc.
- HPLC/UHPLC Waters ACQUITY Arc
The equipment consists of:
– Automatic injector with a temperature-controlled sample carousel.
– Quaternary pump.
– Oven with temperature control and column selector.
– Waters columns:
– XSelect HSS T3 C18 2,5 µm (2,1 x 100 mm)
– XBridge BEH C18 2,5 µm (2,1 x 100 mm)
– XSelect CSH Phenyl-Hexyl C6 2,5 µm (2,1 x 100 mm)
– W2998 PDA (photodiode array) detector. Acquisition range: 190–800 nm.
– W2424 ELS (evaporative light scattering) detector.
– Waters SQ Detector 2 mass spectrometry detector, with ESI, APCI and ESCi ionization sources, and a mass range from 50 to 3000 Da.
Operating standards
Self-service equipment (internal users)
- The analysis will be carried out by the user, following prior training provided by the Service’s technical staff.
- Before using any equipment, users must book it in advance through the IIQ internal application “Other equipment”. Equipment use without prior reservation is strictly prohibited.
- Users are not allowed to modify critical instrument parameters without authorization.
- Any anomaly or incident must be reported to the technical staff.
- Once the analysis is completed, samples, reagents, or solvents must NOT be left on the equipment.
- The workspace must be left clean and orderly.
Equipment operated by the Service’s technical staff
- The Waters ACQUITY Arc HPLC/UHPLC system may only be operated by the Service’s technical staff and by the technical staff of the Chromatography Service.
- The Opentrons OT-2 pipetting robot may only be operated by the Service’s technical staff.
Request for facility
For all other equipment, as well as for external users, requests must be made by contacting the responsible staff via email.